View Single Post
  #6   Report Post  
Posted to uk.d-i-y
Andy Dingley Andy Dingley is offline
external usenet poster
 
Posts: 5,175
Default Microswitches for Triton shower

On 15 Jan, 01:46, "Clive George" wrote:
I think the main microswitches (the ones which switch the two elements,
controlled via the power dial) on my T80i shower are dead


I'd agree with Fred here. However also check the over-temp safety
switches. I've fixed some T80s before now; I've seen dead temperature
switches, but the microswitches seem to last.