Thread: Plumbing Q
View Single Post
  #4   Report Post  
Posted to uk.d-i-y
Roger Mills Roger Mills is offline
external usenet poster
 
Posts: 2,488
Default Plumbing Q

In an earlier contribution to this discussion,
Mr Sandman wrote:

Will one of these -

http://www.kiowa.co.uk/Products/Quic...2_System).html

fit one of these -

http://www.screwfix.com/prods/21289/...OSFEY?ts=03906

if i take the compression nut off?

Tar!

Steve


Very likely - though not guaranteed. Whilst most 15mm compression fittings
use 1/2"BSP threads, some use a finer thread - so the nipple may not screw
on.

Assuming that it *does* screw on, you will - as others have said - need to
find a way of sealing it, since these parts are not *intended* to fit
together. I would be inclined to use liquid PTFE on the threads.
--
Cheers,
Roger
______
Email address maintained for newsgroup use only, and not regularly
monitored.. Messages sent to it may not be read for several weeks.