View Single Post
  #2   Report Post  
Posted to uk.d-i-y
Andrew Gabriel Andrew Gabriel is offline
external usenet poster
 
Posts: 11,175
Default Electronic drive fluorescents

In article ,
Rob G writes:
On 25 Sep, 11:49, (Andrew Gabriel) wrote:

Not going to be able to advise on repair over usenet, except
a common problem with ballasts of that age is arcing between
PCB traces, which is caused by poor washing of the PCB during
manufacture resulting in eventual breakdown, combined with
the manufacturers being new to designing PCB's carrying 600V
pulses and laying the tracks too close together. You might be
able to fix by peeling off an affected track and replacing
with a soldered insulated wire. Other than that, if there's
no obvious damage, you'll have to fire it up with the PCB on
a electronics workbench and try to spot arcing on the board
or inside any components. Needless to say, these have
dangerous voltages inside (significantly worse than mains),
and may remain dangerous a long time after switch-off.

However, I suggest you get a new electronic ballast. Basic
single tube non-dimmable are usually under £10 on eBay.

You're right, Andrew - apart from the challenge of sorting it and it's
going to be a suspect cap I reckon, Ebay looks to be my friend.
This is a twin 70W tube fitting, and I can get a "Philips 2 X TL-D 70
WATT..TWIN BALLAST..WARM START" for effectively pennies. Internet
seems to suggest that TL-D tubes are something special, and what does


TL-D is a bog standard tube (I think it stands for Tube Linear,
Double-ended), 6' in the case of a 70W one.

'Warm Start' mean?


It will preheat the electrodes for a second or so before trying
to start the tube. (Gives longer tube life unless the tubes are
operated for more than 3 hours each time they're switched on,
in which case it's no advantage over instant start.)

--
Andrew Gabriel
[email address is not usable -- followup in the newsgroup]