On Aug 29, 8:38*am, Andy Wade wrote:
kent wrote:
I want to replace the cable going into our standard 3 kW immersion
heater. *I understand that this cable needs to be heat resistant. *Can
anyone tell me if HO5 V2V2 - F cable is suitable?


No, those Vs mean it's a 70 deg. rated PVC/PVC cable. *What you need is
85 deg. harmonised type H07BN4-F (UK CMA code 3183TQ), 1.5 mm^2 3-core.

E.g.http://www.tlc-direct.co.uk/Products...Q3slash50.html


I've always used 2.5mm2 butyl rubber flex, its a fair bit more
capable. Not only does the flex connect to hot terminals, but it also
heats up due to current flow, both need to be taken into account.