View Single Post
  #2   Report Post  
Posted to alt.home.repair
John Grabowski John Grabowski is offline
external usenet poster
 
Posts: 1,934
Default Underground electrical conduit


"SteveB" wrote in message
...
I was blessed with about 800' of 2.5" underground pvc, which I intend to
use to run power to my shop area, about 150' from the house. My ground is
all blowsand mixed with lava rocks from fist sized to Volkswagen sized. I
do have a trencher, but after using it in other areas of my property, have
little faith or expectations for it other than it breaking another tooth.
Is it that important to have this buried that deep, or that it have a
grade? I will run sweeps up so that it is above ground by at least 3' at
the vertical. I intend to put two in the same ditch in case I ever want to
run other lines. As I understand it, Red Hot Blue Glue is good for this
pipe.

Any caveats or suggestions?



18" deep is all that you need although deeper is better in case of future
excavation. I suggest that you put a marker tape just below the soil
surface in case you or someone else digs where the pipe is in the future.

Just regular PVC glue should suffice although it is not a bad idea to use a
primer first. Be sure to put glue on each of the ends that are getting
pushed together.