Is there a reason why radiators shoud not be connected using flexible
hoses? I mean this kind of thing:

http://www.screwfix.com/prods/15015/...oses/Flexible-...

the radiator could then be removed from the wall (for cleaning behind
etc) without disconnecting anything.

maybe it is a bit OTT, but is there a law against it?

Robert


I have two plinth level Smith fan convectors. Both of these were
supplied with regular braided flexible hoses, so you can fit and
remove them under kitchen cabinets and fixed pipework just can't be
used. So I don't see a problem with using these on regular radiators
apart from the fact they're ugly.
Just be careful to choose hoses rated for the temperature - many are
only specced to handle tap temperatures (up to 60C).
Could you use Speedfit or similar plastic pipe instead to get the
flexibility? The 10mm microbore stuff is very easy to work with.
-Antony.