If it's the old style design, you may have a bad termination
thermostat, or a bad defrost timer. What I do, is to wait
till the fridge is badly frosted. Advance the timer into
defrost mode, and check the amp draw of the fridge. Defrost
heaters run about 5 amps. That helps you decide what parts
to change.
--