View Single Post
  #28   Report Post  
Posted to uk.d-i-y
Dave Plowman (News) Dave Plowman (News) is offline
external usenet poster
 
Posts: 43,017
Default Long serial cable

In article ,
John Rumm wrote:
Dave Plowman (News) wrote:
In article ,
Mike Tomlinson wrote:
No - TX and RX and obviously ground. Those are the only connections
on the device DB9.


High baud rate and no hardware handshaking, though 4m is not long for
RS232. I'd suggest a good quality screened cable. The mic cable
suggested by another poster should do the trick. Connect the screen
to the plug body at the PC end.


That's a good idea even if it's also connected to pin 5?


Its better to keep signal ground and screen separate... so generally I
use a core in a screened cable for signal ground, and save the screen
for its intended purpose.


I don't actually have any 3 core screened.

As it happens mic cable works just fine. There was a fault in the wiring
instructions for the serial to RG45 lead they supplied with the D socket
loose - TX and RX reversed. Which to be fair was in the errata at the end
of the instructions. ;-)

--
*Isn't it a bit unnerving that doctors call what they do "practice?"

Dave Plowman London SW
To e-mail, change noise into sound.