In article , Peter Parry
scribeth thus
On Tue, 30 Jun 2009 18:11:23 +0100, tony sayer
wrote:


Anyone ever done this or had any experience of this sort of thing?..


Yes

The wall mounted type with external compressor and the pipes between
them, with the pre charged refrigerant?...


The ones I have done did not use the snapfit connectors but copper
flared pipe. I used an old refrigerator compressor as a vacuum pump
before releasing the refrigerant. In both cases the pipe connectors
needed further tightening after leak testing with soapy water. Both
have lasted 3 years so far.

Instructions tend to be a work of fiction and usually seem to apply to
a different model by a different manufacturer sold in a different
country for a different purpose. Apart from that they are quite
clear.

You need a core drill to make a hole for all the pipe work and need to
be _really_ careful when bending the pipe - it easily kinks. I used
some brown guttering fitted over he pipes to hide the pipes on the
outside of the house.



Thanks for that. There is an expired system there this is a small
community radio station thats always short of the readies and they
simply can't afford to pay for a new installed system being quoted silly
money for repairing the old one and around 2000 plus for a new. Its to
keep there equipment room cooled. I'd use fans if we could but there are
noise and fire complications re that.

Course removing the Gas from the existing system would need to be done I
believe by someone licensed but it could stay in position as its not in
anyone's way, in fact there is a better place where it should have been
put. All very simple to install holes would be very easy to cut etc..
--
Tony Sayer