View Single Post
  #28   Report Post  
Posted to sci.electronics.repair
Franc Zabkar Franc Zabkar is offline
external usenet poster
 
Posts: 1,569
Default Non-Working Cruzer Flash Drive

On Thu, 18 Jun 2009 22:23:23 +0100, Baron
put finger to keyboard and
composed:

However the OP reported an "Over Current Event" Which suggests SC ..


There looks to be a 3-terminal linear 3.3V (?) regulator at the rear
of the PCB in this example:

http://upload.wikimedia.org/wikipedi...x-DSCN0411.JPG

I wonder if it could be a possible suspect.

BTW, the NAND flash memory IC, K9K2G08U0M, is a 3.3V part:

http://www.datasheetarchive.com/pdf-.../DSA-86237.pdf

- Franc Zabkar
--
Please remove one 'i' from my address when replying by email.