Thread: I hate plumbing
View Single Post
  #5   Report Post  
Posted to alt.home.repair
Charles Bishop[_2_] Charles Bishop[_2_] is offline
external usenet poster
 
Posts: 156
Default I hate plumbing

In article
,
Big_Jake wrote:

On Jun 4, 9:28=A0pm, (Charles Bishop) wrote:
If something goes wrong with electrical, the breaker snaps off and I find
the problem and fix it. If something goes wrong with plumbing there is
liquid everywhere, causing more problems before you can fix the original
one.

This one isn't that bad, though.

I took the eschuechon plate off of a single handle Moen shower control so
I could caulk behind it, ditto the tub spout. I caulked, then went to put
the esch plate back on, but the screws are =A0too short. They don't reach
the holes in the valve body. Longer ones don't work because the threads
are nothing like what I have in the truck, they aren't 6/32 or /32, one's
too small and the other too large.

So what I did was keep the esch plate in place and line the holes up with
the screw holes using long 6/32 screws, figuring that I'd come back
tomorrow and thread longer screws in. But, now the control handle won't g=

o
on, its screw is too short.

This is what I think happened: the valve is set too far back from the til=

e
surface so the screws don't reach. When it was installed, they pulled the
body closer (maybe using the tub spout), just to get a screw in. In fact
when I took the plate off, one screw was in, and the other was loose, not
threaded.

I tried to do this but was worried about stressing the copper lines to an=

d
from the valve body. So, the problem is left until tomorrow. I'm going to
try to find longer screws, wish me luck. I'm tired and discouraged now,
but tomorrow is another day.

Any other suggestions? Moen, single handle controller, probably 10 years
old, it has the red/blue stripe on it for hot cold.

--
charles


You need an "extension kit" for the faucet. Here is a link that shows
a posi-temp one:

http://www.bathroomfurnituredirect.c...5-MOE2758.html

A well stocked plumbing supply house should have one in stock for
$30ish. This should have been used when they did the initial install.



Turns out it was easier than I thought, and a good lesson in not working
when I'm tired. The screws /were/ 8/32, I don't kow why I thought
otherwise. Both the hardware store guy and I tried them in the 8/32
display and they didn't work. Went looking again this am at a different
place and he said they were 8/32. Bought 2 3" ones, and it worked fine,
pulled the valve body into place so the handle fit.

I'm not sure yesterday wasn't just a bad dream and I imagined the whole thing.

--
charles