Pioneer plasma turns off: update
DaveC wrote in
obal.net:
Low ESR is -good- for an electrolytic cap.
Uh, right. They were *high* ESR...
Thanks.
one other thing may be to measure the actual capacitance of each
electrolytic cap;I've had some that measured much below their nominal
rating.
and if -some- supplies are high,that could show that another one is being
loaded and the PS is driving harder to pull it up,raising the other
supplies in the process. Seen a lot of that in TEK WFM monitors.
--
Jim Yanik
jyanik
at
kua.net
|