View Single Post
  #2   Report Post  
Posted to uk.d-i-y
Graham.[_3_] Graham.[_3_] is offline
external usenet poster
 
Posts: 172
Default Defrost Timer - follow on


"John" wrote in message
...
Thanks to those who helped. A new timer arrived today and confident that I
understood the circuit I quickly fitted it.

Shock - horror - the compressor wouldn't operate.

I refitted the old timer - manually wound it round - still it wouldn't
operate.

Out with the meter - found the circuit to be open circuit to the motor.
What had I done????


Took the terminal cover off the compressor to see if I could track down
the fault - plugged it in again - and it fired up.

Had I disturbed a connection?


No - I did the job so quick and the motor was so hot that the compressor
stalled when I applied power and then tripped the overheat trip.

Working fine now.



Bejesus! You should have worked more slowly, then charged yourself
for the second hour.

--
Graham.

%Profound_observation%