View Single Post
  #5   Report Post  
Posted to alt.home.repair
aemeijers aemeijers is offline
external usenet poster
 
Posts: 5,149
Default Surround receptical box with foam board

wrote:
On Wed, 15 Apr 2009 07:50:53 -0700 (PDT), sid
wrote:

I have one particular corner that I intend to use a lot of 'Owens
Corning' foam board. Can anyone tell me of any know issues with
surrounding the receptacle w/ pink foam board ?
I have seen several discussions in this list talking about how the
stuff is not flammable, but can I safely butt it right up to
receptacle boxes ?

Thanks

Sid.


Just be sure there is no gap between the box and cover that exposes
the foam.

Unless he his bringing the box out to the new surface level, he needs an
extension ring to meet code. They're cheap and easy to install. Unless
box is crowded, you don't even need to disconnect the outlet or switch,
just undo the mount screws and slide the ring (more like a sleeve) over
it. I installed 4 or 5 around here where idiot previous owner added T&G
paneling, or 5/8 rock, without bothering to move the boxes out. Yes,
the inspector will not regard the foam as something sparks from a failed
device should land on.

--
aem sends...