You need to maintain the same number of square inches. If the
existing is 6" round, the square inch capacity is about 27 square
inches. Stop at any tin shop, explain your problem, ask them to
make a transition that will work.
If you are framing a wall directly under the glulam, add two lally
columns that are swallowed by the wall and go through the glulam.
--