On Jan 28, 12:15*pm, (AnthonyL) wrote:
The low pressure hot water pipe to the kitchen tap has a weeping elbow
joint in an awkward position at the bottom of the kitchen unit. *It is
a soldered joint and it takes about 2 days to fill a shallow drip
tray.

Is there any way to fix it without having to dismantle all the unit
around the sink?


Do you have enough length to:
- cut out the elbow joint plus some pipe
- form a new (longer) elbow out of some sort of elbow + pipe
- fit new elbow with two straight push-fit or compression joints?
eg http://www.screwfix.com/prods/60835/...ush-Fit/Conex-
Cuprofit-Straight-Coupling-15mm

and/or:
http://www.screwfix.com/prods/47156/...15mm-Pack-of-2

or possibly work out something with a bit of flexy?