View Single Post
  #15   Report Post  
Posted to rec.crafts.metalworking
Bob Engelhardt Bob Engelhardt is offline
external usenet poster
 
Posts: 2,473
Default Follow up - Problem with Hypertherm Powermax 380 plasma cutter

Boy, do I feel stupid! It was just a matter of correct adjustment of
its regulator!!

Bob Engelhardt wrote:
...
The PC has a built-in air regulator & gauge. It's set to 60 psi, as it
it is supposed to be. The pressure doesn't drop when the torch trigger
is pulled & gas flows. ...


That's not true - it does drop & it's supposed to be adjusted while the
air is flowing. There's even a special setting to allow it to flow
without energizing the torch. 'Cause I didn't RTFM, I adjusted it
static, then it was too low with gas flowing.

My apologies for wasting the time of those who replied,
Bob