On Nov 18, 10:20�am, George wrote:
On Mon, 17 Nov 2008 08:13:07 -0500, Speedy Jim





wrote:
George wrote:
We have a bathtub that has a drum trap - which appears to be lead, as do
the connecting pipes. �(The stack is cast iron.) �The trap is leaking.


I'm thinking to cut the lead pipe on the stack side of the trap, use a
rubber coupling to join that end to PVC from there to the tub. �Is there
reason NOT to do this? �The alternative would be to unsolder the lead
pipe from the stack Y, and connect the PVC there. �This looks like it
would take big heat, and might never get clean enough for the new joint
to seal well.


TIA,
George


All lead tub drainage was common from turn of century till 1920's.


I would cut the lead close to the stack entrance and use a
Mission-style coupling:
http://www.fernco.com/plumbing/flexi...tock-couplings
1056 series coupling to adapt to PVC.
If you can get to the stack connection, put the coupling over
the solder thimble where the lead attaches; that will help prevent
distortion of the lead. �...


That all makes sense, except it's so tight there. �The (lead) pipes are
bent to fit.

I see that Genova lists a PVC drum trap (75715). �At first blush, that
might simplify things. �I gather that they're not recommended (and often
not code), but would that be a really BAD idea?

And, re the PVC drum: could it be mounted upside down, so the cleanout
was on the top? �The current drum has an opening in the bathroom floor,
which could make the cleanout accessible.

Thanks,
G- Hide quoted text -

- Show quoted text -


drum traps are essentially obsolete and no longer used.

regular PVC traps can be easily snaked thru the tub control lever
location.

you cant snake a drum trap, the snake just winds itself into a knot
inside the drum.......

besides the top of the drum is just another leak spot.

do yourself a big favor, dont patch replace it ALL, unless you want to
revisit this again,'

piping tends to all fail close in time, design life i guess.

add distrubing things just leads to sooner faliures