View Single Post
  #6   Report Post  
Posted to alt.home.repair
Wayne Boatwright[_3_] Wayne Boatwright[_3_] is offline
external usenet poster
 
Posts: 95
Default Just had a thought about surge suppressors...

On Thu 25 Sep 2008 04:35:03a, Pete C. told us...


Nate Nagel wrote:

Does anyone make a plug in suppressor that has TWO coax connections? I
just realized that I was considering running both cable and an antenna
connection to each TV in my house, but all the surge strips that I have
everything connected to only have connections for one coax (I guess
they assumed that someone would have either cable or an antenna but not
both...)


I haven't seen one. You really should be doing your coax surge
suppression at the point of entry for both your feeds. There are in-line
F connector surge suppressers that install quite nicely at the ground
block outside the house.

I had a couple cable modems blown up by nearby lightning strikes shortly
after I moved here. I drove a new ground rod, connected a ground block
to it with a short wire and installed the in-line suppressers at the
ground block. Since this installation I've had plenty more nearby
lightning strikes, but haven't lost any more cable modems or other
equipment. I don't use any additional coax suppressers in the house
either.


An odd thing happened when we installed a coax suppressor. This was in a
new home with a new Cox coax feed. Our cable modem worked fine, but we
lost about half the cable stations from our cable box to TV. It was not a
channel filter. Cox advised us to remove it, and all channels were back.
I haven't tried another suppressor.

--
Wayne Boatwright

*******************************************
Date: Thursday, 09(IX)/25(XXV)/08(MMVIII)
*******************************************
Countdown till Veteran's Day
6wks 4dys 17hrs 3mins
*******************************************
The wise open their minds, but a fool
opens his mouth.
*******************************************