On Sep 20, 4:21 pm, Franc Zabkar wrote:
On Fri, 19 Sep 2008 20:05:27 -0700 (PDT), poster
put finger to keyboard and composed:

Microwaveburned the fast fuse and 'rectifier' 2x062 on this schematic
http://geocities.com/anglomont/mw.jpg
Replaced it with hvr 6x2 diode however once again it and fuse burned
though "high voltage rectifier" diode hvr1x stayed ok
(hvr 6x2 short, hvr 1x conducting 0.25 ma when tested with 4.5v)
Magnetron ok, so what could be the reason for this-perhaps capacitor
or some contact with oven interior along points A or B?
thanks in advance


I can't find anything in theMicrowaveRepair FAQ that discusses the
high voltage protector diode:

http://www.repairfaq.org/sam/micfaq.htm

I did find a datasheet for your HVR6x2 diode, though:http://www.dccomponents.com/products...igh_Voltage/HV...

This device consists of two back-to-back HV diodes, one drawn larger
than the other, the smaller one with a 1500V reverse breakdown
voltage, the larger with 6000V. AFAICS, if your HV capacitor were to
go open, then the smaller diode could see a reverse voltage close to
the peak secondary voltage of the power transformer (~2000V). This
would exceed its rating and presumably it would fail.

So IMO the capacitor is one possible suspect, although I would think
that anything which allowed a good capacitor to charge in the reverse
direction may also cause the same failure. Therefore it may be wise to
replace the HV diode as well, just in case it is leaky. Also check
that the magnetron's filament is not shorted to the case.

- Franc Zabkar
--
Please remove one 'i' from my address when replying by email.


also here-http://www.repairfaq.org/REPAIR/F_micfaq2.html#MICFAQ_017
i found this

Problem: Fuse blows when initiating cook cycle.
Possible causes:

1. Defective interlock switches or misaligned door.
2. Shorted HV capacitor.
3. Shorted HV diode.
4. Shorted magnetron (probably won't blow main fuse but HV fuse if
used).
!5. Defective triac.
6. Old age or power surges.
7. Defective HV transformer.
!8. Short in wiring due to vibration or poor manufacturing.