View Single Post
  #33   Report Post  
Posted to sci.electronics.repair
Jim Yanik Jim Yanik is offline
external usenet poster
 
Posts: 3,103
Default Cell Phone -- What remains wet?

Jim Adney wrote in
:

On Tue, 24 Jun 2008 21:50:46 -0700 (Dave Platt)
wrote:

In article ,
Jim Adney wrote:

I have a friend who tells of starting his cleaning process by running
his boards thru the wash cycle of his kitchen dishwasher, with soap.


Bob Pease swears by this process. He writes (in "Troubleshooting
Analog Circuits", a book I most strongly recommend) that when he's
working on PC-board circuits which require low leakage currents, he'll
run 'em through the dishwasher, standard cycle, using a normal load of
Calgonite detergent.


I have the book, and I read it years ago, but I'd forgotten that Bob
also did this.

-
-----------------------------------------------
Jim Adney

Madison, WI 53711 USA
-----------------------------------------------


I used to use the auto dishwasher trick at the Orlando TEK field office,on
2236 DMM boards,cured many leakage problems.used Calgonite,BTW.

And we had a drying oven that had a negative pressure inside.

--
Jim Yanik
jyanik
at
kua.net