View Single Post
  #13   Report Post  
Posted to alt.binaries.schematics.electronic
amdx amdx is offline
external usenet poster
 
Posts: 415
Default Coleman Exciter Circuit


"donald" wrote in message
. ..
amdx wrote:
"BobW" wrote in message
...
"amdx" wrote in message
...
Interesting thread. Glad to hear you got yours running and sorry to
hear
that they closed doors on the factory.
Don't rush me Oppie,
I haven't got it working yet. I rewound the coil, varnished and baked
it twice. Now I'm waiting on the capacitor.
Mike :-)

Hurry up, Mike! You fill us with anticipation and then you make us wait.
Very inconsiderate.

8-}

Bob


Ok, Bob here's the end story.
I started the Coleman Generator problem thread about two weeks ago.
It quit producing power after about 1 hr 15 min.
After dissassembly I found an overheated exciter coil, a defective
capacitor and a burned open foil on the pcb.
I removed the bad 19 turn coil and wound a new one in the stator. I got
a quart of motor varnish at a motor repair shop and revarnished the coil.
I baked the stator in my wifes oven! I varnished and baked the unit twice
just for safety.
(I did note that one of the fiber insulators was not properly placed in
the stator, I think this is where the coil rubbed the stator and shorted,
causing the failure) I replaced the bad capacitor and repaired the open
foil.
This morning I reassembled the unit and fired it up. It works!
I applied a 3300 watt load and it's been running almost 4 hrs at 119.2
volts.
Mike

Do you have time to post some pics ?

donald

I wish I had taken some pictures especially of the capacitor. After I cut
it open and inspected it, I called my 14yr old son in and shower him the
rolled contruction and
how the connection points were in the center of the length.
Mike