View Single Post
  #6   Report Post  
Posted to alt.binaries.schematics.electronic
noname[_4_] noname[_4_] is offline
external usenet poster
 
Posts: 3
Default Help to ID blown resistor

Mouser and Digikey only had .47 ohm, so I got 10 of them.
If one blows, I'll parallel 2 or 3, and if those also go, I'll just get a new
power supply, there are same model # but higher revision numbers for
$110.
Thanks for the help.




On Sat, 14 Jun 2008 13:57:36 -0700, "RST Engineering \(jw\)"
wrote:

Yes, but the true problem is that whatever caused the fusable resistor to
"blow" will cause its replacement to blow also unless fixed.

Jim