Vox AC30 , AC30CC2X, 2005
Gareth Magennis wrote:
"N_Cook" wrote in message
...
Removed the grey coating and remnant parts of the metalisation/ MO sum to
about 1.5 ohm. The joining section is about 1 x 1 mm with a neat hair-line
crack across it and no sign of any heating there.
So mechanical breakage, I will dig out my microscope and take a photo of
it.
Before removing coating, was definitely 2.2 ohm markings with white band
(if) for x16 presumably referring to that 1 x 1 mm section, so x32 violet
banded one would have a something like 0.7 x 0.7mm intercept region and a
green band x8 would have more like 1.4 x 1.4 mm fusing area.
Anyone care to give a reason for shock induced fracture just at that
point?
I suspect a Roadie dropped it off the stage.
Splurt! No no stop... you owe me a keyboard now!
Ron(UK)
|