View Single Post
  #3   Report Post  
Posted to rec.antiques.radio+phono,sci.electronics.repair
n cook n cook is offline
external usenet poster
 
Posts: 1,220
Default Carvin X50B tube amp

Peter Wieck wrote in message
...
On Feb 25, 7:33 am, "N Cook" wrote:
Amp seems to work perfectly well, being repaired for minor problem, no
succeptibility to microphony or tinging distortion.
Testing the 2x EL34, gains are good and matched but after a minute on
heated C/H insulation check, the resistance gradually decreases to 1M for
one and 0.5M for the other.
What problems will this lead to if continued use, and how quickly ?

--
Diverse Devices, Southampton, England
electronic hints and repair briefs , schematics/manuals list

onhttp://home.graffiti.net/diverse:graffiti.net/

It means that the tubes are not precisely matched. Sadly, "matching"
tubes these days is typically based only on "gain" and done for a
quick claim to inflate prices.

No problems if each tube has an individual bias adjustment, and you
watch over it. Even if they are biased together and that bias is
attended-to, there should be no problems. How many hours on these
tubes and are they driven to extremes or not?

What are you testing with?

http://hereford.ampr.org/Tube4.php?tube=6CA7

Peter Wieck
Wyncote, PA

Unknown age, matched GT tubes, no date on tubes
used by a pub rock band
tested on Avo CT160