On Feb 24, 8:42*am, smcjensen wrote:
I have a furnace blower I want to use as a shop exhaust fan. *It's a
GE ECM motor meaning it has electronic controls mounted on the motor,
however, you can remove the control module and behind it are three
wires going to the motor, black, blue, red. *There are no other wires
coming from the motor. *There's also a capacitor mounted to the
housing. *The motor says it's 120/240 volt 1 HP. *I have 120 juice
close to the motor and I have a 220 outlet for band and table saw not
so conveniently located but presumably I could tap into that if
necessary.

So, which colors on the motor connect to which colors in the home
wiring?

Which color wire would go to the capacitor?

If I have to tap in behind the higher voltage outlet what's the best
way to work in an on/off switch other than using the breaker as my
switch?


If you haven't already you may try a google search for the particular
ECM motor you have. The ones I know of are actually brushless DC
motors and the "control module" is what converts the AC to DC. You
can't remove the controller and hook the motor directly to AC. Try
posting all nameplate data on the motor.