Nick Mueller wrote:

Design flaw: The *bolt* is designed to take the shearing force. You are
fired! That is wrong by design! It always are the two parts and the
friction between the two and the preload given by the bolt.


I'm inclined to agree with Nick here. The few times I've made this
mistake myself in the past, the joint has come loose. Sure, there are a
few instances in which it can be okay to load a bolt in shear (a shackle
for example:
http://www.1st-chainsupply.com/image...shackleCM.jpg),
but they're cases in which loosening isn't an issue. Mostly it's a bad idea.

Best wishes,

Chris