Thread: Ping Iggy...
View Single Post
  #4   Report Post  
Posted to rec.crafts.metalworking
Paul Paul is offline
external usenet poster
 
Posts: 104
Default Ping Iggy...

Todd Rich wrote:
Well, I'm not sure what I was smoking, but having the pressure switch
wired into FWD & DCM, I am getting the motor starting up and staying
running with the cutout switch on or off.

http://www.driveswarehouse.com/docum...spede/PC1M.pdf

The paramaters are correct in 0-20 and 2-00, so I'm not sure what I'm
missing.

0-20 is b00001
2-00 is 0

Help?


Check the setting of 0-19, the factory default is '0' which only allows
control from the keypad or the comm port, try setting 0-19 to '1' which
should give control from the keypad or external terminals such as FWD.

Regards
Paul


--
-----------------------------------------
It's a Linux world....well, it oughta be.
-----------------------------------------