Correct, it's two single pole switches in parallel. Install a junction box
in the attic with the feed in it. Run a two wire cable to the fan motor. Run
a two wire cable to each bathroom switch. Connect the neutral in the
junction box to the fans neutral. Connect the hot in the junction box to
both white wires going to the switches. Connect both black wires coming back
from the switches to the black that goes to the motor.




"Christopher Nelson" wrote in message
...
I've heard of bathroom fans which have the blower at the top of the
duct, just under the roof rather than just above the bathroom
ceiling. And I heard a suggestion that they can be used to vent
multiple bathrooms with one blower. But I'm having trouble imagining
how that would be wired so it could be turned on in either of two
bathrooms. That's not a three-way switch.