"N Cook" writes:
Eeyore wrote in message
...
N Cook wrote:
There are 3 HF transformers
More likely one transformer and 2 chokes, unless you have a specific
reason to say otherwise.
Why would chokes bridge the "no man's land" isolation strip between HV and
LV areas ?
No, probably transformers instead of opto-isolators (on the feedback
and drive).
Personally, I wouldn't even attempt to do any serious troubleshooting
on a supply of this type unless there was no inexpensive replacement.
I would check the obvious - ESR of e-caps, open high value startup
resistors, and such. But beyond that, these tend to be infinite
frustration sources.
--- sam | Sci.Electronics.Repair FAQ:
http://www.repairfaq.org/
Repair | Main Table of Contents:
http://www.repairfaq.org/REPAIR/
+Lasers | Sam's Laser FAQ:
http://www.repairfaq.org/sam/lasersam.htm
| Mirror Sites:
http://www.repairfaq.org/REPAIR/F_mirror.html
Important: Anything sent to the email address in the message header above is
ignored unless my full name AND either lasers or electronics is included in the
subject line. Or, you can contact me via the Feedback Form in the FAQs.