Default Mitsubishi VS-4506R "ghosting"


"D-unit" cof42_AT_embarqmail.com wrote in message
...
I have this model and have noticed that on warm up,
the picture will have a series of ghost images off to
the right of the first image that subsequently fade
out after about the 5th generation...

This problem used to almost go away after warm up
but is steadily getting worse.

I will try to describe the problem another way.

If I had a white screen with a vertical black line in
the middle, I would see 4 or 5 more black ghost type
images (lighter and lighter) off to the right.

This problem is present using any of the inputs.


It also displays no color on the S-video input. Black & white
only.


Any help would be appreciated.

Don B




Just for the record.

Problem: C2B1 100uf 16v.

Solved.

db