View Single Post
  #1   Report Post  
Posted to sci.electronics.repair
jango2 jango2 is offline
external usenet poster
 
Posts: 125
Default AVR-1905 Denon receiver amp fooled me

Symptom: does not switch on. Will switch on unpredictably once every
50 tries. Digital 5volts is always available. Clock oscillator can be
observed at the syscons pins only if other vertical boards are plugged
in. Grounds for digital and analogue seem to be floating. Display may
either be blank or have some leds glowing.
The first time i powered up it worked. I gave an estimate. Now i'm
fooled. Ever since then it switched on just once. Help. What role does
the 6ch input board play in the syscons clock oscillator (a 12 Mhz 3
legged ceramic resonnator).
Jango