Hugo Nebula wrote:

IIRC, that can be acceptable if there is only one room in the loft, and
the stairways themselves are protected (i.e. door to other habitable
rooms that open onto the same landing or hall are fire resisting)


It's not really. The stair itself needs to be separated by a full
height enclosure with a door at the top landing, or separated from the
floor below by an enclosure and door at the bottom.


Would not a hall/landing that has all rooms that open on to it protected
by fire doors not count as such an enclosure?

--
Cheers,

John.

/================================================== ===============\