View Single Post
  #4   Report Post  
geoff
 
Posts: n/a
Default Poxy Potterton boiler again...

In message , Rob
writes
On Thu, 03 Jul 2003 11:03:39 GMT, (Colin Swan)
wrote:

, I am thinking of building
a cupboard around the boiler. Are there any regs to do with this? Any
advice on how much space to leave around, ventilation, etc?


metoo Colin, I also have a Suprima which used to cut out during
winter. I realise you replaced the PCB, but maybe the refurb isn't
perfect?


Not perfect ?

No Suprima (or other) boards go out of my factory if they are not
working properly.

This board has been working for some time now, and the problem seems to
be that either there is a problem with the pilot valve, delivery of
spark to the electrode or flame sensing - which can be due to a number
of factors

I've solved, for the time being, my problems by going over
all the main joints on the PCB with a soldering iron. Some of them
were too close to risk tho.

And I've also enclosed mine in a kitchin unit. Made sure to drill
plenty of holes above and below. Seems OK like this. Apart from that
cutting out of course! Good luck

regards

-Rob


Oh and for the programmers and pedants: /metoo


--
geoff