Backup sumppump problem
On Jun 8, 10:26 am, " wrote:
On Jun 8, 9:41?am, (Doug Miller) wrote:
In article . wrote:
I just installed a Basemen****chdogEmergency sump pump. The pump
works as described but I noticed that when it fires it tries to pump
water out but unless I jiggle the pump and dislodge what I think is an
air pocket the pump will not pump out the water. Once I do this the
pump gets rid off all the water in the sump right away. I was not able
to use a Y pipe due to the way the other pump was install. I had to
use 90 PVC fittings. Could this be the problem?
Did you drill a small hole in the side of the pipe just above the pump, as the
installation instructions state?
--
Regards,
Doug Miller (alphageek at milmac dot com)
It's time to throw all their damned tea in the harbor again.
its best to run a completely seperate drain line, like out the wall
for the back up pump.
the two pumps shouldnt share any plumbing to provide maximum protection- Hide quoted text -
- Show quoted text -
Hi guys,
I removed the pump, clenaed the check valve and repositioned the pump
so that it was a bit more level. Something worked as it's now pumping
water out beautufully. Thanks for the help.
Javier
|