View Single Post
  #4   Report Post  
Posted to rec.woodworking
alex alex is offline
external usenet poster
 
Posts: 24
Default TS Motor stopping periodically.

Hi,

I think it is TEFC but I'll check tonight.
The blade is sharp and I'm removing about 1/8-1/4 at a time.
Its plugging directly into a 20A outlet.

Thanks

Alex

On Jun 7, 9:28 am, (Doug Miller) wrote:
In article om, alex wrote:
maybe someone could suggest what is going on with my TS lately. I have
an older Beaver contractors table saw. which has a 3/4 110 v motor and
a magnetic switch.


When I use the saw with a standard rip or combination blade it runs
fine. But, if I use a dado blade after a while the motor shuts off. If
I try to start it right away it won't start. If I wait a minute it
will start and then shut down immediately. If I wait a few minutes it
starts up again and then runs fine for a while and then the whole
process repeats itself.


Is the motor overheating? I'm not doing a lot of cutting with it.


It could be, yes. More information would help, though:
- is the motor open, or TEFC (totally enclosed fan-cooled)?
- are your dado blades sharp?
- how much wood are you trying to remove at once with the dados?
- do you have the saw plugged directly into an outlet, or are you using an
extension cord?

--
Regards,
Doug Miller (alphageek at milmac dot com)