adder1969 wrote:
On Apr 20, 10:48 am, Norbet wrote:
I've just noticed recently that my central heating hasn't been working
- the boiler works for hot water, but although the thermostat
indicates operation it's not actually managing to swicth the boiler
on.



Surely if it indicates demand for heating it's something in the
switching that's wrong? With mine it's always the batteries but you
said you tried that.


It could simply be the motorised valve as well. Nothing to do with the
radio at all.


I mean the chain goes:-

stat via RF - receiver (is it showing call?) - motorized valve (is it
moving?) - micro switch on valve (has it got a broken wire?) - boiler
stat (is that working?) - pump and ignition mechanism.

Plenty of potential problems in that chain.

Need to poke around with a mains test screwdriver or a meter all along
to see what is not doing what it should.

One quick test might be to try and move the motorized valve by hand..if
that all works you know the problem is 'upstream'..