Default New condenser, old evaporator

On Apr 18, 7:00 am, wrote:
the evaporator needs to be clean so the freon goes to a gas . if the
condenser fan isnt running your not pulling the heat off the freon
before its pumped by the compressor.

http://www.minibite.com/america/malone.htm


yes, the evaporator does need to be clean, otherwise the refrigerant
won't vaporize, but it is clean. i took it out and checked it myself.

the fan not running would make the a/c far less efficient and would
put another mark against the compressor overheating, but it would make
it even less likely that the compressor is receiving a liquid from the
evaporator. as soon as the freon passed the expansion valve, it would
be hot, and start to boil.

if the evaporator could not do its job in vaporizing the refrigerant,
wouldn't it freeze up?