Lurch wrote:
http://www.screwfix.com/search.do;js...ABOCSTHZOCFEY?...
If you load the instruction manual for the rotary the accuracy which
is quoted in +/- mm per m is 1 which seems an awful lot. At 5m you are
going to be 5 mm out (possibly)
Most fixed levels are accurate to around 1mm in 1000mm so not really
any different.
A slight difference being that if you were transferring a level a long
distance with a conventional level, then you would (well should!)
reverse it each time you extend the level - that way you reverse out any
error each time. With a laser level you would not do this, so the base
accuracy needs to be better really.
--
Cheers,
John.
/================================================== ===============\
| Internode Ltd -
http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/