View Single Post
  #5   Report Post  
Posted to alt.home.repair
 
Posts: n/a
Default Adding electrical outlet question


"DerbyDad03" wrote in message
ups.com...
On Feb 20, 6:16 pm, "Paul" wrote:
hello - I am adding a couple of outlets in my unfinished basment,
something I have done before (though never in this house - new (1985)
house)
However, with this circuit, when I add an outlet (black/white/ground
NM), and I test the outlet with circuit tester , I get "hot/neutral
reversed".
When I flip the switch that I believe is at the end of this circuit,
(this switch controls an overhead light, and only has cable going into
it) my circuit tester (on my "new" outlet) changes from "hot/nuetral
reversed" to "hot/ground reversed". As far as I know, there is nothing
(outlet, junction box, switch) between my new outlet, and the wall
switch.
The light switch has a black wire, and white wire that has been
painted black going in, as well as bare ground.
Any suggestions as how to wire outlet, re-wire wall switch?
Many thanks,
-paul


Where did you get the wires that you connected to the new outlet too?

Open every box in the chain, and map out the colors, and inspect for fried
devices. Something is reversed or loose or shorted out somewhere. The
painted white in the switch box indicates a switch leg, so it isn't the
'end' of the circuit. You need to go upstream from the box that switchleg is
hooked to, all the way to the breaker. Something is bass ackwards. I also
recommend a DIY wiring book- they will show what colors are supposed to be
on what screws, and what colors are wirenutted together where.


aem sends...