View Single Post
  #2   Report Post  
Posted to alt.home.repair
DK DK is offline
external usenet poster
 
Posts: 257
Default Gas Fireplace - Fan Runs - Very little comes out

On Thu, 15 Feb 2007 07:58:56 GMT, wrote:

Hello All

I have a customer thats experiencing fan problems on her gas
fireplace.

The fan wall switch has two settings hi and low. I can see the fan
spinning on different speeds and it's going in the right direction.
However this translates to virtually no air flow out the top. Barely
perceptable on hi and nothing on low.

What do you think is happening here? Could the vent be plugged??

BTW I do have some gas pro's scheduled to come. An electrician stated
everything was fine just a couple days ago.

Thanks
Dale


Where there is masonry, there are often plugs.

But many of those early fans were not designed to be felt as they
were underpowered. I've seen the same problem on many of the early
firebox fan systems.

You have to use the candle test to determine if they are working.
Watch the smoke when holding the candle in front of the exit vent.