Default Sears air compressor throws breaker

On Feb 5, 12:09 pm, wrote:
On Jan 30, 5:02 pm, "Bob S." wrote:



On Jan 30, 4:19 pm, wrote:


I have come in possession of a Craftsman model 919.165200, 5hp, 20
gallonaircompressorthat when turned on runs for a few seconds then
throwsabreakerin my shop. Anyone have a clue as to why or how to
repair? Anyone come across this problem before?


TIA


Jerry


Things that will cause thebreakerto trip:
1. using an extension cord with thecompressor.
2. other units running when thecompressorkicks in.
3. bad or under rated circuitbreaker. (need 15-20A)
4. a bad pressure switch on thecompressor.
5. a bad capacitor on thecompressormotor.
6. a bad motor on thecompressor.


Bob


Since it is running a few seconds, (like 10-15 seconds), might that
indicate that the run capacitor is the culprit? I have no way to test
the capacitors. It has 2, 1 of which is a G.E., (I think it is the
run capacitor), & the other is a Mallory, (which I think is the start
capacitor). I can find a replacement for the G.E., but I would have
to replace the Mallory with a different brand. The Mallory is 400-480
MFD, 165 VAC, but the nearest replacement that I can find, w/o having
to buy about $100 worth, is 400-480 MFD, 125 VAC.

Searsdoesn't list the capacitors as replacements & the complete motor
w/capacitors is $230. At that price I might as well buy a newcompressor& tank.

Jerry


It was the G.E run capacitor. I ordered one from
www.surpluscenter.com, installed it & the compressor ran with no
problem. Thanks to everyone for your suggestions.