View Single Post
  #5   Report Post  
Posted to uk.d-i-y
John John is offline
external usenet poster
 
Posts: 4
Default Old Central Heating problem

wrote:

On 6 Feb, 11:00, John wrote:
A friend has an old back boiler heating system (Baxi, I think) and an
upstairs radiator is leaking - bottom of radiator has rusted through.
Due to lack of funds and as the system is so inefficient that they
don't use it, they wanted to drain it down or isolate the radiator.

All of the radiators have only one regulator valve, the other side
being a plain 90 degree union. There do not appear to be any drain
points on the system unless on the boiler behind the gas fire. The
system appears to be fed from the same header tank as the DHW system
and there is no obvious way to isolate the cold water supply to the
heating without also isolating the hot water tank - the only visible
wheel valve being to isolate the hot water tank.

The only idea I have is that it any isolating valves may be below the
hot water tank which is in a cupboard above and at the end of the
bath, the whole bathroom floor BTW is approx 6 inches higher than the
rest of the upstairs floor which makes me think that it is to
accommodate plumbing.

Apologies for the length of this post. All suggestions gratefully
received.



It is very easy to add a drain point anywhere on half inch pipe, just
connect a dracula tap. (Self cutting tap that clamps onto the side of
an existing pipe.) The a valve can be fitted, or the rad replaced.
Note that even if a crap performer, a sometimes half warm rad still
gives out some heat.

However I wonder if your system may be gravity circulation, which
would use much bigger pipes.

Fernox leak sealer might give you more time to arrange a real repair.

screwfix.com item 13768.

If one rad has rusted through, it wont be too long before the others
follow suit. Your primax cylinder makes it impossible to use any
additives to prevent corrosion. The whole system sounds lousy, money
will be needed soon.


NT

Thanks everyone for the info, I'll pass it on. Indeed, the system does
sound lousy.