View Single Post
  #2   Report Post  
Posted to sci.electronics.repair
jango2 jango2 is offline
external usenet poster
 
Posts: 125
Default Infocus LP250 Wont Start.


Does the standby indicator glow?
The chameleon power l.e.d. reports the state of the unit.

"solid green: The projector is plugged in, or the projector has been
turned on and the
software has initialized. The projector has been turned off and the
fans have stopped.

blinking green: The Power button has been pressed and the software is
initializing, or the
projector is powering down and the fans are running to cool the lamp.

blinking red: A fan or lamp failure has occurred. Make sure the vents
aren't blocked. Turn off the projector and wait one minute, then turn
the projector on again. If the projector
has been working for 2000 hours or more, replace the lamp and reset the
lamp timer by pressing Volume +, then Volume -.

solid red: An unidentifiable error: please contact Technical Support."

Which of the above four modes does the l.e.d. report?
Jango