Pull out the spark plug and squirt a small amount of gas into the hole,
replace the plug and try to start it. If it runs for a few seconds, it may
be an indication that it's not getting fuel, in which case I would open the
carburetor and see if the float is stuck,and clean it. If gas sits in the
unit for any period of time it turns to jelly and things that should move
get stuck, and small jets get clogged. Also be sure there isn't a low oil
switch preventing it from running


wrote in message
oups.com...
Hello. I live in Kosovo and I have an ACME generator, made in Italy.
It is fairly new and has been recently serviced, although it is
difficult to get it serviced.

My problem is that when I try to start it- with a full tank, the fuel
on, choke on and on button on and a good looking spark plug- it starts
for about 4 seconds and then dies, not to be started again until I've
regained my patience, which is usually the next day.

I need this machine for the work I do and was wondering if anyone can
give me any tips on what to look at.

Thank you,

Karl