Frigidair electric range oven broiler and bake elements
Hi,
Checked fuse or something equivalent?
Hello Tony,
House main panel fuses are OK. According to the schematic diagram,
downloaded from Frigidaire website for this model, shows only 1 thermal
circuit breaker for the temperature probe.
Meantime Sears give me the part numbers (sensor: 970316217002) and the
"timer" (hopefully it is the EOC's number): 970318183603N
After taking apart the front of the range-where the EOC is located-the tab
on the EOC reads: Spitfire Control Inc. Model No.: 318183900. While this
is only of this man nitpicking interest: where the part numbers come
from?
By the way: resetting the range (disconnecting) gives no error code either.
To do:
1. How to test the temperature probe
2. How to test the EOC
Any other idea?
Thanks for your trouble.
|