View Single Post
  #1   Report Post  
Posted to sci.electronics.repair
[email protected] nakman8@comcast.net is offline
external usenet poster
 
Posts: 1
Default Teac X-7R capstan stalling

I just replaced the belt with a PRB generic. Now about half the time I
have to nudge the flywheels
to get the capstans going.Happens in both directions. I cleaned and
lubed the flywheels and checked endplay. Don't have a schematic for
unit. Wondering if there is a startup circuit I should be checking?
Belt seemed to be a little tight so I gave it a good stretch. No
affect.
Any help will be appreciated.

Thanks,Dennis