View Single Post
  #3   Report Post  
Posted to alt.home.repair
jolt jolt is offline
external usenet poster
 
Posts: 45
Default Gas fire place difficult to light


"dave" wrote in message
ups.com...
I have a gas fire place that is operated by a switch (light switch).
It worked fine until last year. I have the pilot lit, and when I turn
on my switch, nothing happens. I have to open up the lower louver and
hit the red ignitor switch a few times.
Last year, I only had to do this the first time after turning my pilot
back on. So far this year, I have had to do it every time.
Is this a simple fix, or do I need a fixit guy?

Thanks


First thing to do would be to clean the pilot burner. Basic style fireplaces
use a powerpile generator to create millivoltage to power the control
circuit. A low pilot flame can result in low power to the control resulting
in intermittent opening or complete failure to open.