Concrete weep holes
srazor wrote:
A customer has a brick flower box 3x3' that does not drain water (no
weep holes) Do I drill them through the mortar joint or brick? Do I
need to insert PVC pipe to line the weep holes to prevent freeze damage?
TIA
Always drill thorugh the mortar, not the brick: mortar can repaired
easily, while a destroyed brick would need to be replaced entirely.
The PVC won't help so don't waste your time with it. Old time weep holes
would be made with a simple length of cotton rope laid in the bottom of a
mortar joint to wick out moistu the cotton would eventually rot away
but that wouldn't matter. Today, masons frequently leave one butt-joint
completely free of mortar and put in a metal vent to keep out insects
while allowing out water.
John
--
Remove the dead poet to e-mail, tho CC'd posts are unwelcome.
Mean People Suck - It takes two deviations to get cool.
Ask me about joining the NRA.
|