You really need to figure out what load it is supporting. You might
have short studs above a header. Or you might have a full-height header
(like two 2x10s). And this might be taking some load from above, or
not. Even your idea of leaving the studs (if there are studs), removing
drywall, and adding glass, is not really safe unless you know what the
load is. Drywall does actually have more than a decorate purpose (e.g.,
for shear forces), but the glass will be entirely decorative.

But in all likelyhood, if it is just a simple shallow header, with
short studs above it, and assuming there is no loading from above, then
you could just remove the whole thing and put in glass with no trouble.

-Kevin